APC SRTG6KXLI nepārtrauktas barošanas avots (UPS) Divkāršā-konversija (tiešsaiste) 6 kilovoltampērs 6000 W 3 Maiņstrāvas izvade (-s)

Product Code: SRTG6KXLI
Barcode 0731304411826
Brand: APC

To purchase this product you must be registered in our system.

 

Specification
ac outlet types: C13 coupler, C19 coupler
ac outlets quantity: 3 AC outlet(s)
audible alarm modes: Alarm when on battery, Low battery alarm, Overload alarm
audible alarm(s): Yes
automatic battery test: Yes
battery life (max): 5 year(s)
battery recharge time: 4 h
battery technology: Sealed Lead Acid (VRLA)
battery voltage: 96 V
certification: CE, EN/IEC 62040-1
cold start: Yes
crest factor: 3:1
depth: 620 mm
display type: LCD
eco mode: Yes
emergency power off (epo): Yes
emergency power off (epo) connector: Yes
ethernet lan (rj-45) ports: 1
form factor: Compact
height: 178 mm
hot-swap battery: Yes
input frequency: 40/70 Hz
input operation voltage (max): 285 V
input operation voltage (min): 100 V
international protection (ip) code: IP20
led indicators: Yes
noise level: 55 dB
non-operating altitude: 0 - 15240 m
operating altitude: 0 - 2011 m
operating relative humidity (h-h): 0 - 95%
operating temperature (t-t): 0 - 40 °C
output frequency: 50/60 Hz
output operation voltage (max): 240 V
output operation voltage (min): 220 V
output power: 6000 W
output power capacity: 6 kVA
output voltage total harmonic distortion (thd): 2%
package depth: 790 mm
package height: 275 mm
package weight: 59 kg
package width: 590 mm
product colour: Black
serial interface: Yes
smartslot: Yes
storage relative humidity (h-h): 0 - 95%
storage temperature (t-t): -15 - 45 °C
surge energy rating: 600 J
ups topology: Double-conversion (Online)
usb port: Yes
waveform: Sine
weight: 51.9 kg
width: 440 mm

Description
Automatic restart of loads after UPS shutdown

Automatically starts up the connected equipment upon the return of utility power.

Automatic self-test

Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Battery failure notification

Provides early-warning fault analysis on batteries enabling timely preventive maintenance

ECO Mode

Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection

LCD Status Display

Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.

Cold-start capable

Provides temporary battery power when the utility power is out.

Safety-agency approved

Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Resettable circuit breaker

Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)

Power conditioning

Protects connected loads from surges, spikes, lightning, and other power disturbances.

Input Power Factor Correction

Minimizes installation costs by enabling the use of smaller generators and cabling.

Generator compatible

Ensures clean, uninterrupted power to protected equipment when generator power is used.

Frequency and voltage regulation

Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.

SmartSlot

Customize UPS capabilities with management cards.

Network manageable

Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.

Serial connectivity

Provides management of the UPS via a serial port.

InfraStruXure Manager Compatible

Enables centralized management via the APC InfraStruXure Manager.

LED status indicators

Quickly understand unit and power status with visual indicators.