APC USV SMX3000RMHV2UNC X 3000VA Rack/Tower Network Card (Speditionsversand)

APC

SMX3000RMHV2UNC

Jauns

Availability Boost and Trim Automatic Voltage Regulation (AVR) Gives higher application availability by correcting low and high voltage conditions without using the battery.Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances.Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature.Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.Disconnected battery notification Warns when a battery is not available to provide backup power.Manageability Network manageable Provides remote management of the UPS over the network.Audible alarms Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.LED status indicators Quickly understand unit and power status with visual indicators.Serial Connectivity Provides management of the UPS via a serial port.USB connectivity Provides management of the UPS via a USB port (not available on all models).Disconnected battery notification Warns when a battery is not available to provide backup power.Serviceability User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replacedPredictive failure notification Provides early-warning fault analysis ensuring proactive component replacement.Resettable circuit breakers Enables a quick recovery from overload events.Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenanceAdaptability Adjustable voltage-transfer points Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.Safety Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

UPS topologyLine-Interactive
Output power capacity3 kVA
Output power2700 W
WaveformSine
Input frequency50/60 Hz
Output operation voltage (min)208 V
Output operation voltage (max)240 V
Output frequency regulation50/60 Hz
Automatic Voltage Regulation (AVR)Y
Surge energy rating645 J
Hold time (min)2 ms
Hold time (max)10 ms
Efficiency98.5%
Emergency Power Off (EPO)Y
Noise level55 dB
Surge protectionY
Audible alarm(s)Y
Auto-restartY
AC outlet typesC13 coupler, C19 coupler
Power plugC20 coupler
AC outlets quantity9 AC outlet(s)
Number of output IEC jumpers2
SmartSlotY
Battery technologySealed Lead Acid (VRLA)
Battery capacity738 VAh
Typical backup time at full load6.3 min
Typical backup time at half load18 min
Battery life (max)5 year(s)
Battery recharge time3 h
Hot-swap batteryY
Automatic battery testY
Form factorRackmount/Tower
Product colourBlack
Rack capacity2U
Cable length2.44 m
LED indicatorsBattery replacement
CertificationC-tick, CE, EN 50091-1, EN 50091-2, EN 55022 Class A, EN 60950, FCC Part 15 Class A, GOST, IRAM, UL 1778, VDE, REACH, PEP, EOLI
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 45 °C
Operating relative humidity (H-H)0 - 95%
Storage relative humidity (H-H)0 - 95%
Operating altitude0 - 3000 m
Non-operating altitude0 - 15000 m
Sustainability certificatesGreen Premium, RoHS
Width432 mm
Depth667 mm
Height85 mm
Weight37.3 kg
Package width596 mm
Package depth869 mm
Package height85 mm
Package weight45.4 kg
Rack mount kitY
Cables includedRS-232
Temperature sensorY
ManualY
Software CDY
Products per pallet8 pc(s)
Harmonized System (HS) code85078000
Nominal output voltage230 V
Nominal input voltage230 V
Packaging contentWeb/SNMP Management Card